Diagnostic/Prescreening

Wave Analyzer Medica 700 Wavefront Aberrometer

Fast and fully automatic:
7-in-1 measurement solution

The WAVE ANALYZER is a fast and effective automatic aberrometer that provides 7 different detailed measures in one easy-to-use solution. With wireless connectivity, it facilitates the sharing of results with patients and transfer of data for follow-up monitoring or action.

  • Based on wavefront and Shack-Hartmann technology
  • Large touch screen makes it simple to navigate or follow the progression of measurement cycle
  • Easy data sharing with clear and customizable result reports
  • Comprehensive measurements :
    • 1/100 diopter refraction for day and night vision
    • Low and high order aberration with simulation of vision quality
    • Topography and pupillometry for contact lens fitting and keratoconus detection
    • Retro-illumination of crystalline lens for opacity check and cataract screening
    • Scheimpflug-based pachymetry and tonometry for secured glaucoma screening

Contact Us

Submit Product Support Ticket

Note: Submitting a support ticket will take you to a separate website.

Medica 700 Front
WAM700

Wave Analyzer Medica 700 Back

FAST & FULL AUTOMATIC MEASUREMENT PROCESS

  • All measures are automatically performed by the device once the chin rest level is adjusted.
  • Intuitive navigation and measurement cycle progression on the large touch screen
  • Performs 7 measurements in 90 seconds.

EASY DATA SHARING

  • Clear and customizable result reports
  • XML-based technology for easy data and image transfer

How many functions does WAM700 perform?

7 fully-automatic functions including: Ref / Ker / Topography / Pupilometry/ Tonometry / Packymetry/ Wave HOA & LOA analysis plus retro-illumination


How long does it take to run all 7 functions?

90 seconds to automatically complete all 7 functions


Does it need a PC or software?

No PC is needed. It is built into the machine. Viewing can be done through a network with remote access.


Can we extract reports for an EHR?

Reports can be exported as a PDF for import into an EHR.


How does it measure topography?

24 Placido rings measuring 6144 points


How does it measure Wavefront?

Shack-Hartmann Wavefront Sensor with 100,000 points


How many viewer licenses are delivered with WAM700?

Up to 25 viewer licenses


Do I need the Internet for WAM700?

The Internet is required only if you will export XML, PDF or access remotely.


Can I connect a TV or PC monitor to WAM700?

Yes, via a VGA cable or a VGA to HDMI converter


Is WAM700 DICOM compatible?

No, there are no DICOM possibilities.


Do we need a USB3 port in the PC?

No, USB 3.0 is not a requirement.


Can we do a Meibomian analysis with WAM700?

No


What is the resolution of the images?

1080 x 1920 pixels


Can I do a video?

No, only pictures


Can I change the contrast and brightness of the images?

Yes but this can be done only on the pachymetry images.


What is the minimum pupil size?

The minimum pupil size is 2.0 mm.


Do I need to drill my table to mount WAM700?

No, drilling is not needed.


Do you have a soft contact lenses library for WAM700?

No, only RGPs


Do you have a scleral lenses library for WAM700?

No, only RGPs


Can we do tear film analysis or BUT with WAM700?

No.


How many Placido rings does WAM700 have?

24


How many points are analyzed?

6,144


Can I measure the elevation of both the anterior and posterior cornea?

Not on both, only on the anterior.


Does the software have cases of corneal pathology such as keratoconus, where the corneal apex is decentered off the visual axis?

Some cataract and HOA/LOA cases


Can I do multiple map displays?

No


Can I do OD/OS comparison displays?

Yes


Can I do an overlay of the image for OD/OS?

No


Can I do a full study of the pupil diameters?

Yes


Can I simulate NaFl (fluorescein)?

Yes


Can I do pictures and videos of the anterior segment?

No


Does it include features for keratoconus assessments?

No


Can I do printouts of the display?

Yes


Does it have Scheimpflug technology?

Yes, but static


Does AnaEyes have corneal ectasia monitoring and treatment?

No, it does not any monitoring module.


Can I do keratoconus progression on patients?

Yes


Is WAM700 an Anterior Segment Optical Coherence Tomography?

No, it is not an AS-OCT.

Diagnostic/Prescreening

Medica 700 FrontMy most recent purchase was the WAM Wavefront Analyzer Medica 700. This device has been a key addition to my practice especially now as the amount of audits for medical necessity have significantly increased over the past few years. I feel my skills in designing rigid contact lenses around the interesting corneal surfaces has greatly increased by being able to see exactly what I am trying to avoid or reshape. Also the ability to identify these cases early makes patient expectations with their quality of sight and management plan more clear.

Simaan ShiniODCollege Station, TX

Diagnostic/Prescreening

Medica 700 FrontI recently purchased the WAM700 (Wave Analyzer Medica 700 Wavefront Abberrometer) after reviewing other similar instruments on the market. This instrument is great! By doing 7 different measurements within 2 minutes per eye, it is a time saver and money generator! My staff loves the ease of this machine, I like the data it provides without having to use multiple different devices and the patients are impressed with the technology. I highly recommend the WAM700.

Beth Pyle-SmithODEstrella Mountain Eye CareAvondale AZ